Gateway Operations
Development Preview
This page is for inspecting the current process and locating problems; it provides no production availability guarantee. A successful monitoring response, a successful Stub write, or a successful upload endpoint response cannot replace acceptance with real devices and failure scenarios. The endpoint behavior described here is based on the registered routes at commit b1a16cbc.
1. Routine Checks
Docker environment:
docker compose ps
docker compose logs -f gateway
curl -fsS http://127.0.0.1:8080/api/health
curl -fsS http://127.0.0.1:8080/api/metricsGET /api/health returns health data such as process version, uptime, MQTT connection status, and Tag count; GET /api/metrics returns Prometheus text format. These two endpoints currently require no token; restrict access through listen scope, firewall, or reverse proxy to avoid exposing system information.
If you have corrected and verified the systemd installation paths yourself, you can check:
systemctl status fastbee-gateway
journalctl -u fastbee-gatewayThe paths in the shipped installation script and unit are not yet unified; do not assume the service is correctly installed.
2. Log Management
2.1 Log Locations
| Log source | Path / method | Notes |
|---|---|---|
| systemd journal | journalctl -u fastbee-gateway | Service lifecycle logs |
| Application logs | spdlog output (console/file sink) | Runtime logs |
| In-memory log tail | GET /api/debug/logs | Roughly the last 50 entries, for remote diagnostics |
2.2 Viewing and Filtering
sudo journalctl -u fastbee-gateway -f # follow in real time
sudo journalctl -u fastbee-gateway -n 100 # last 100 lines
sudo journalctl -u fastbee-gateway -p err # errors only
sudo journalctl -u fastbee-gateway --since "2026-10-01" --until "2026-10-02"2.3 Log Levels
Supported levels (from most to least verbose): trace → debug → info → warn → error → critical → off. How to change:
# Config file: gateway.json → "system": { "logLevel": "debug" }
# Or a startup argument:
fastbee-gateway --log-level debug3. Runtime Information After Authentication
After logging in and carrying a Bearer token, you can use:
| Endpoint | Operational use and limitations |
|---|---|
GET /api/mqtt/status | View connection status, broker, publish/subscribe statistics, and error/reconnect counters; counters do not mean data was reliably delivered |
GET /api/overview/status | View system resources (CPU/memory/temperature/disk) and runtime status |
GET /api/overview/devices | View internal device totals and online/offline statistics; the current online model does not equal physical communication acceptance |
GET /api/overview/traffic | View MQTT byte, message, publish, subscribe, and reconnect statistics |
GET /api/drivers/health | View the driver health summary; it cannot be used to judge fieldbus health while drivers are not registered |
GET /api/debug/tags | Actively perform one pollOnce() and return Tags and statistics |
GET /api/debug/logs | Returns roughly the last 50 in-memory log entries, not a complete persistent log archive |
4. Monitoring and Alerting Integration
4.1 Prometheus / Grafana
The gateway provides a Prometheus-compatible metrics endpoint (no authentication required):
curl http://<gateway-ip>:8080/api/metricsExample Prometheus scrape configuration:
scrape_configs:
- job_name: 'fastbee-gateway'
scrape_interval: 15s
static_configs:
- targets: ['<gateway-ip>:8080']
metrics_path: '/api/metrics'4.2 Recommended Alert Thresholds
| Metric | Warning threshold | Critical threshold | Action |
|---|---|---|---|
| CPU usage | >70% | >90% | Check whether the polling interval is too short |
| Memory usage | >80% | >95% | Check the SQLite cache size |
| Disk usage | >80% | >95% | Clean up logs and caches |
| CPU temperature | >70°C | >85°C | Check heat dissipation / ambient temperature |
| MQTT disconnection | >1min | >10min | Check the network and broker |
| Device offline | >5min | >30min | Check field devices / wiring |
4.3 Alarm Engine Monitoring
The industrial alarm engine (AlarmEngine) supports 5 alarm types and is linked to TagEngine through TagChangeObserver:
# View active alarms / statistics / rule list
curl -H "Authorization: Bearer $TOKEN" http://<gateway-ip>:8080/api/alarms/active
curl -H "Authorization: Bearer $TOKEN" http://<gateway-ip>:8080/api/alarms/stats
curl -H "Authorization: Bearer $TOKEN" http://<gateway-ip>:8080/api/alarms/rules
# Acknowledge an alarm (operator response)
curl -X POST -H "Authorization: Bearer $TOKEN" http://<gateway-ip>:8080/api/alarms/<ruleId>/ackAlarm types: LEVEL (threshold, supporting HH/H/L/LL four levels), DEVIATION (deviation), RATE_OF_CHANGE (rate of change), QUALITY (quality), DIGITAL (digital). The alarm state machine is NORMAL → ACTIVE → ACKED → RETURNED → NORMAL.
4.4 Driver Health Monitoring
The driver health monitor (DriverHealthMonitor) uses a 6-state connection state machine:
DISCONNECTED → CONNECTING → CONNECTED → RECONNECTING → FAILED → ISOLATEDcurl -H "Authorization: Bearer $TOKEN" http://<gateway-ip>:8080/api/drivers/health
curl -H "Authorization: Bearer $TOKEN" http://<gateway-ip>:8080/api/drivers/<name>/healthHealth metrics: state (connection state), consecutiveErrors (consecutive errors), avgLatencyMs (average latency), lastHeartbeat (last heartbeat), isolated (whether automatically isolated). After consecutive errors reach the threshold the driver enters FAILED; after a sustained timeout it enters ISOLATED, then automatically attempts recovery on the autoRecoverMs schedule (default 60 seconds).
5. Configuration and Data Backup
5.1 Backup Scope
- The
gateway.jsonactually in use, user data, and any subsequently modified configuration. - Secret material such as
.secret.key; it must be isolated from public documentation, images, and logs, and stored according to the organization's secret management policy. - Business data, logs, and certificates in Compose named volumes; first confirm the mapping between volumes and real paths.
- Custom systemd units, reverse proxy, and broker authentication/TLS configuration.
5.2 Export and Import
The configuration export/import endpoints are genuinely available in the current code (via ConfigManager):
# Export
curl -H "Authorization: Bearer <token>" \
http://<gateway-ip>:8080/api/system/config -o gateway-backup.json
# Import
curl -X POST -H "Authorization: Bearer <token>" \
-H "Content-Type: application/json" \
-d @gateway-backup.json \
http://<gateway-ip>:8080/api/system/configYou can also copy the configuration file directly, or schedule backups with crontab:
#!/bin/bash
# /usr/local/bin/fastbee-backup.sh — back up the configuration every early morning
BACKUP_DIR="/backup/fastbee-gateway"
DATE=$(date +%Y%m%d_%H%M%S)
mkdir -p "$BACKUP_DIR"
cp /etc/fastbee-gateway/gateway.json "$BACKUP_DIR/gateway-$DATE.json"
find "$BACKUP_DIR" -name "*.json" -mtime +30 -deleteDuring restore, also verify configuration paths, key matching, file ownership, and write permissions. A read-only configuration mount blocks .secret.key and API configuration writes; the problem cannot be masked by repeated restarts alone.
6. Firmware Upgrade (OTA)
The designed upgrade flow is: download firmware → verify → back up the current version → install the new version → restart the service → verify startup, with rollback on failure. Currently POST /api/system/upgrade only acknowledges receipt of the file and returns uploading; verification, installation, and rollback are not implemented. Until then, upgrade manually with the deb package:
scp fastbee-gateway-1.1.0-arm64.deb root@<gateway-ip>:/tmp/
ssh root@<gateway-ip> "dpkg -i /tmp/fastbee-gateway-1.1.0-arm64.deb && systemctl restart fastbee-gateway"Version check:
fastbee-gateway --version
curl -H "Authorization: Bearer <token>" http://<gateway-ip>:8080/api/system/info7. Common Troubleshooting
7.1 The Web UI Does Not Open or Static Assets Are Missing
- Confirm you are accessing
http://<host>:8080, not8443, for which no HTTPS service is implemented. - Confirm the actively read key is
web.port, and check port mapping and firewall (ss -tlnp | grep 8080,ufw status). - Source runs use the relative
web-src; start from the source root to avoid working-directory errors. - Path differences between the installation script's
web/and the realweb-src/, and between systemd's/optand CMake's/usr, must be corrected first.
7.2 MQTT Does Not Connect or Changes Do Not Take Effect After Saving
- The default configuration points to
192.168.1.100, not the Compose service namemosquitto. - Check in order:
ping <broker_ip>→nc -zv <broker_ip> 1883→ DNS/routing → broker process and logs. - Check whether
ENC(...)values have a matching key; ciphertext that fails decryption cannot be used as credentials. The FastBee AES authentication password is generated on the platform side in Device Management. - Check that anonymous access is limited to an isolated development environment, and that production broker authentication/TLS is consistent.
PUT /api/mqtt/configsaves only a subset of fields and does not reconnect; verify the real configuration and restart in a controlled window.- Client auto-reconnect options do not equal offline data replay; the active callback currently skips data while disconnected.
7.3 No Collected Values or Writes Fail
- Check that
drivers, devices, and Tags use runtime fields rather than legacy UI/documentation fields. - Modbus addresses use zero-based
registerAddr; confirm real libmodbus results rather than Stub results. - The current primary code blocker is that the application does not register configured drivers with TagEngine; correct configuration cannot bypass this problem.
- Use the debug APIs to locate the issue:
GET /api/debug/tagsactively collects once, andPOST /api/debug/writeperforms a manual write test. - Serial link checks: RS485 A/B wiring, termination resistors, baud rate / slave address consistency, and bus load.
7.4 Alarms Do Not Trigger or Flap Frequently
- Check whether the rule is enabled (
enabledinGET /api/alarms/rules), whether the Tag has data updates, and whether the threshold is reasonable. - If an alarm flaps near the threshold, increase
deadband(for example, with a threshold of 80°C and a deadband of 5°C, the value must fall below 75°C after triggering before the alarm returns to normal).
7.5 A Driver Is Automatically Isolated
Check isolated and the consecutive error count in GET /api/drivers/health, and inspect the serial connection, device power supply, bus address, and baud rate configuration; after fixing the underlying communication problem, the driver will retry according to the automatic recovery mechanism.
8. Performance Tuning
| Optimization | Configuration | Effect |
|---|---|---|
| Deadband filtering | Tag configuration deadband | Reduces invalid reporting |
| Tiered polling intervals | Critical Tags 100-500ms, regular Tags 1000-5000ms | Avoids polling low-frequency data at high frequency |
| Batch reads | Merge consecutive registers into one read | Reduces Modbus transactions |
| QoS tiers | QoS 0 for properties, QoS 1 for events | Balances reliability and performance |
| Heartbeat interval | Increase keepAliveSec appropriately | Reduces heartbeat overhead |
On low-memory devices, shrink the log and cache footprint; for non-critical Tags, increase pollIntervalMs appropriately.
9. Debug Endpoint Security Boundaries
POST /api/debug/readcurrently ignores the device/Tag IDs in the request and performs a fullpollOnce(); on real devices this can trigger extra bus load.POST /api/debug/writeis a manual debug entry point, not cloud MQTT reverse control; production code does not callsubscribeFunction.POST /api/debug/pingconcatenateshostdirectly into astd::system()command, creating a command injection risk. Do not open it to untrusted users or networks; fix the input handling or isolate the endpoint first.POST /api/system/rebootactually triggers a system reboot command; strictly limit the token and network exposure surface.- The authentication middleware mainly verifies the token; do not infer from it that admin, operator, and read-only roles are enforced on every sensitive route.
10. Features That Must Not Be Treated as Completed Operational Capabilities
- Offline replay: the active reporting path does not use
SqliteCacheto save and resend disconnected batches. - Configuration reconnect: the MQTT PUT does not perform the automatic reconnect implied by the UI; client reconnect primitives do not constitute a complete operational guarantee either.
- Factory reset: the current endpoint only logs and returns
resetting; no configuration cleanup is performed. - OTA: the current upload endpoint only returns the file name, size, and
uploading; firmware verification, installation, and rollback are not performed. - Reverse control: the production function subscription and command execution chain is not connected.