Modbus Device Monitoring Scenario ​

Scenario Description ​

Periodically collect Modbus RS485 slave device data (temperature/humidity/air quality) via poll trigger. Collection results are automatically reported to the platform via MQTT and displayed on an OLED screen.

Required Peripherals ​

PeripheralTypeDescription
uart_rs485UART(1)RS485 communication port
modbus_sensorMODBUS_DEVICE(51)Modbus sensor device
oled1LCD(36)OLED display (optional)

Complete Configuration Process ​

This scenario requires first configuring Modbus RTU serial port and slaves, then creating poll collection, MQTT reporting, and OLED display actions in peripheral execution.

AreaFieldExample Value / Status
Status OverviewRisk LevelLow
Status OverviewEnabled Tasks0
Status OverviewTimeout Rate0%
Status OverviewTotal Polls / Success / Failed / Timeout0 / 0 / 0 / 0
Basic ConfigEnable Modbus RTUEnabled
Basic ConfigPeripheral Config SelectionSelect configured RS485/UART peripheral
Basic ConfigTransfer TypePassthrough (Raw HEX frames)
Basic ConfigDE Pin (RS485)14
Sub-device NameTypeSlave AddressDevice InfoEnableActions
Temp/HumidityCollection2FC04 @0 x2 [2 mappings]ONEdit / Map / Delete
PM25-10Collection1FC03 @0 x2 [2 mappings]ONEdit / Map / Delete
Weather LouverCollection4FC03 @500 x8 [6 mappings]ONEdit / Map / Delete

Step 1: Configure Peripherals ​

💡 Prerequisite: Modbus sensor device and OLED display must be configured in advance (refer to examples/54-modbus-sensor-devices.md)

Required Peripherals:

  • uart_rs485 - UART(type: 1) - RS485 communication port
  • modbus_sensor - MODBUS_DEVICE(type: 51) - Modbus sensor device
  • oled1 - LCD(type: 36) - OLED display (optional)

Step 2: Configure Peripheral Execution Rules ​

Rule: Poll Modbus Sensor Every 5 Minutes

  1. Click Peripheral Execution in the left menu

  2. Click the Add Rule button

  3. Fill in basic configuration:

    • Rule Name: Collect Environment Quality
    • Report Data: ✅ Enabled (auto-report collection results)
    • Enable: ✅ Enabled
  4. Configure trigger:

    • Trigger Type: Select Poll Trigger
    • Poll Interval: 300 (300 seconds = 5 minutes)
    • Response Timeout: 1000 (1000ms)
    • Max Retries: 2
    • Request Interval: 100 (100ms)
  5. Configure actions (3 actions needed):

    Action 1: Poll Modbus Task 0

    • Action Type: Select Modbus Poll
    • Target Peripheral: Enter modbus-task:0 (fixed format)
    • Task Index: [0]
    • Execution Delay: 0

    Action 2: Poll Modbus Task 1

    • Action Type: Select Modbus Poll
    • Target Peripheral: Enter modbus-task:1
    • Task Index: [1]
    • Execution Delay: 200 (200ms delay to avoid bus conflicts)

    Action 3: OLED Display Data

    • Action Type: Select OLED Display
    • Target Peripheral: Select oled1
    • Display Template:
      #EnvMonitor
      Temp: ${modbus_temp.value}°C
      Humidity: ${modbus_humi.value}%
      CO2: ${modbus_co2.value}ppm
    • Execution Delay: 500 (500ms delay to wait for data collection to complete)
  6. Click the Save button

💡 Tip:

  • targetPeriphId format is fixed as modbus-task:N, N is device index
  • syncDelayMs must be set between multiple Modbus actions to avoid bus conflicts
  • When "Report Data" is enabled, collection results are automatically reported via MQTT

Method 2: JSON Configuration File Import ​

Communication Parameter Description ​

ParameterValueDescription
pollResponseTimeout1000Maximum 1 second wait for slave response
pollMaxRetries2Retry 2 times after failure
pollInterPollDelay100100ms interval between two requests

Data Flow ​

  1. Poll trigger fires every 300 seconds
  2. ACTION_MODBUS_POLL collects data from task:0 and task:1 sequentially
  3. Collection results are stored in sensor cache
  4. OLED display action references cached data to update screen
  5. reportAfterExec: true causes collection results to be reported via MQTT

Precautions ​

  1. Modbus Ready: Poll trigger automatically checks if Modbus is ready; skips if not ready
  2. Action Interval: Set syncDelayMs between multiple MODBUS_POLL actions to avoid bus conflicts
  3. Failure Backoff: No retries within 30 seconds after communication failure to avoid blocking the system
  4. Async Execution: Modbus polling executes in FreeRTOS async tasks, not blocking the main loop