ADC Analog Input
Overview
ADC (Analog-to-Digital Converter) is used to collect analog signals such as light intensity, smoke concentration, flame intensity, soil moisture, and other analog sensor output voltages. ESP32 has a built-in 12-bit ADC that can convert 0~3.3V analog voltage to 0~4095 digital values.
Supported Peripheral Types
| Type | type Value | Description |
|---|---|---|
| GPIO_ANALOG_INPUT | 15 | GPIO analog input (simple mode) |
| ADC | 26 | ADC dedicated mode (with attenuation/resolution parameters) |
ADC Parameter Description
| Parameter | Description | Options |
|---|---|---|
| attenuation | Attenuation coefficient | 0=0dB(1.1V), 1=2.5dB(1.5V), 2=6dB(2.2V), 3=11dB(3.3V) |
| resolution | Resolution (bits) | 9, 10, 11, 12 |
| sampleRate | Sample rate | 0=Default |
Common configuration:
attenuation=3(full scale 3.3V) +resolution=12(0~4095)
Before connecting ADC, verify input voltage, attenuation, resolution, and WiFi impact on ADC2; when troubleshooting on-site, it is recommended to save raw values, converted values, and sampling intervals simultaneously.
Available Pins
- ESP32 ADC1: GPIO 32-39 (recommended, still available when WiFi is enabled)
- ESP32 ADC2: GPIO 0, 2, 4, 12-15, 25-27 (not available when WiFi is enabled)
- ESP32-C3: GPIO 0-4 (ADC1)
- ESP32-S3: GPIO 1-10 (ADC1), GPIO 11-20 (ADC2)
Important: When using WiFi, only ADC1 channel pins can be used!
Typical Sensor Applications
| Sensor | Output Range | Description |
|---|---|---|
| Photoresistor | 0~3.3V | Lower voltage with stronger light |
| MQ-2 Smoke | 0~3.3V | Higher voltage with higher concentration |
| Flame Sensor | 0~3.3V | Lower voltage when flame is closer |
| Rain Drop Sensor | 0~3.3V | Lower voltage with more rain |
| Sound Sensor | 0~3.3V | Higher voltage with louder sound |
| Soil Moisture | 0~3.3V | Lower voltage with higher moisture |
Configuration
Method 1: Web Interface Configuration (Recommended)
Before saving ADC peripherals, verify input pins, range conversion parameters, and whether voltage divider protection is in place.
Step 1: Navigate to Peripheral Management Page
- Open a browser and navigate to the ESP32 IP address
- After logging in, click Peripheral Configuration in the left menu
Step 2: Add ADC Analog Input Peripheral
Click the Add Peripheral button
Fill in the configuration:
Field Value Description Peripheral ID light_sensororsmoke_sensorUnique identifier Name Light IntensityorMQ-2 Smoke SensorDisplay name Peripheral Type GPIO Analog Input (type: 15) or ADC (type: 26) Simple mode or dedicated mode Pin Configuration 36or34Must use ADC1 pins Attenuation 33=11dB(0-3.3V full scale) Resolution 1212-bit=0-4095 Click Save
Step 3: Verify Configuration
- Find the newly added peripheral in the peripheral list
- Click the Enable toggle
- Check real-time ADC values
⚠️ Important: ADC1 pins (GPIO 32-39) must be used when WiFi is enabled
Method 2: JSON Configuration File Import
Add the following configuration to the peripherals array in data/config/peripherals.json:
Light Sensor
{
"id": "light_sensor",
"name": "Light Intensity",
"type": 15,
"enabled": false,
"pins": [36],
"params": {
"initialState": 0,
"pwmChannel": 0,
"pwmFrequency": 1000,
"pwmResolution": 8,
"defaultDuty": 0
}
}ADC Dedicated Configuration (Smoke Sensor)
{
"id": "smoke_sensor",
"name": "MQ-2 Smoke Sensor",
"type": 26,
"enabled": false,
"pins": [34],
"params": {
"attenuation": 3,
"resolution": 12,
"sampleRate": 0
}
}Multi-Channel ADC Collection
{
"id": "adc_multi",
"name": "Environment Monitoring ADC",
"type": 26,
"enabled": false,
"pins": [36, 39, 34, 35],
"params": {
"attenuation": 3,
"resolution": 12,
"sampleRate": 0
}
}Peripheral Execution Integration
As Poll Trigger Data Source
ADC values can be periodically collected by peripheral execution rules via ACTION_SENSOR_READ(19):
{
"targetPeriphId": "smoke_sensor",
"actionType": 19,
"actionValue": "",
"useReceivedValue": false,
"syncDelayMs": 0,
"execMode": 0
}As Platform Trigger Condition
Collected ADC values are reported via MQTT and can be used for platform trigger conditions:
{
"triggerType": 0,
"triggerPeriphId": "smoke_sensor",
"operatorType": 2,
"compareValue": "2000"
}Meaning: Trigger rule when smoke sensor ADC value > 2000
Voltage/Current Sensors
For scenarios requiring ADC value conversion to actual physical quantities, refer to:
- Current Sensor — ACS712 and other current measurements
- Voltage Sensor — Voltage divider measurements
Engineering Units and Quality
Industrial AI (analog input) can perform conversion through persistent parameters such as signalMode, conversionEnabled, calibratedVoltage, inputMin/inputMax, and engineeringMin/engineeringMax. The default configuration preserves raw ADC behavior; front-end parameters must match the engineering-unit range, and readings whose quality indicates conversion failure, disconnection, or out-of-range must not be treated as a normal zero value.
Conversion Fields
After selecting 0-10V, 0-20mA, 4-20mA, or custom linear mode, the Web UI automatically enables engineering-unit conversion and fills in common input ranges; advanced calibration items are collapsed by default, and usually only the engineering-unit lower and upper limits need to be filled in.
| Field | Default | Description |
|---|---|---|
signalMode | 0 | 0=raw value, 1=0-10V, 2=0-20mA, 3=4-20mA, 4=custom linear |
conversionEnabled | false | Whether to output engineering units; when off, raw ADC reporting is kept |
inputMin / inputMax | Derived from signal type | Input signal range; 4-20mA defaults to 4/20 |
engineeringMin / engineeringMax | 0/100 | Engineering-unit range corresponding to the sensor nameplate |
engineeringOffset | 0 | Field calibration offset of the conversion result |
clampEnabled | false | Clamp when out of range; when off, the current reading is invalid and reporting stops |
vRef | 3.3 | ADC reference voltage |
voltageRatio | 1 | Divider restoration ratio for the 0-10V front end |
shuntResistance | 165 | Current-loop shunt resistor, in Ω |
inputGain / inputOffset | 1/0 | Analog front-end gain and voltage offset |
The conversion formula is EU=(INPUT-INPUTmin)/(INPUTmax-INPUTmin)×(EUmax-EUmin)+EUmin+engineeringOffset. In 4-20mA mode, the ADC voltage is first converted to mA using the shunt resistor and front-end gain; in 0-10V mode, it is first converted to the input voltage using the divider restoration ratio. ESP32 pins cannot directly accept 10V or a current loop; a suitable divider, isolation, or shunt front end must be used.
The new fields are backward compatible: old configurations lacking the new fields use safe default values and keep their original behavior.
Acquisition Quality and Reporting
After engineering-unit conversion is enabled, the value and the acquisition quality are handled separately:
quality | qualityCode | Meaning |
|---|---|---|
valid | 0 | Input is within the configured range |
low | 1 | Input is below range but has not reached the 4-20mA disconnection threshold |
high | 2 | Input is above range but has not reached the 4-20mA short/overdrive threshold |
disconnected | 3 | 4-20mA input is less than inputMin - 1mA; for the standard range, less than 3mA |
short | 4 | 4-20mA input is greater than inputMax + 1mA; for the standard range, greater than 21mA |
invalid_config | 5 | Signal type, range, engineering-unit range, or other configuration is invalid |
GET /api/peripherals/read?id=<peripheral ID> returns rawValue, value, valueValid, quality, and qualityCode together. When clamping is off, an abnormal reading has a value of null and valueValid=false; when clamping is on, the original abnormal quality is still kept and only the value is limited to the engineering-unit endpoints. When conversion is enabled and the mode is not raw, periodic MQTT additionally reports a <peripheral ID>_quality property, e.g. ai_soil_temp_quality=disconnected; when abnormal and not clamped, the value property is omitted but the quality property is still reported.
A plain analog read in Peripheral Execution directly reuses the conversion result of the peripheral configuration, so range and calibration parameters are maintained in a single place; the action's own scaleFactor/offset can still be used for a final secondary adjustment.
The legacy read categories for voltage-divider and current sensors have separate action calibration parameters — see Voltage and Current — to avoid double conversion; for NTC thermistor temperature measurement, see NTC Thermistor. For ADC resource lifecycle, sampling failures, and multi-consumer behavior, see the ADC lifecycle document.
Save a disabled draft first, complete the wiring/resource review, then enable the peripheral, read, verify quality, and finally enable the periodic rule. Calibrate using actual measurements from a multimeter or a standard source; raw * 3.3 / 4095 must not be treated as a measured voltage.
Notes
- WiFi and ADC2 Conflict: ADC2 is not available when WiFi is enabled; production environments must use ADC1 pins
- ESP32 ADC Non-linearity: ESP32 native ADC has non-linearity at both ends (near 0V and 3.3V), with better accuracy in the middle range
- Reference Voltage: ESP32 internal reference voltage is approximately 1.1V, expanded range through attenuation coefficient
- Multi-Channel Collection: Same ADC type peripheral can configure multiple pins, system polls sequentially
- Sampling Noise: Recommend multiple sample averaging for ADC readings (system has built-in 10-time averaging for current/voltage sensors)